Thông số Giá trị
Model KV-XL202
Type Serial communication unit
Communication standard RS-232C
Connection interface European terminal block with 7 poles (detachable) × 2 ports
Electrical termination (terminator)
Transmission rate 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 bps
Transmission method Full duplex
Data format Start bit: 1 bitData bit: 7 bits, 8 bitsStop bit: 1 bit, 2 bits
Error detection Parity: Even, odd, none
RS/CS flow control ON or OFF
Transmission distance 15 m49.2′
Number of transmission units 1
Refresh Automatic refresh, direct refresh, inter-unit synchronization refresh
Serial communication functions Non-procedure, PROTOCOL STUDIO, Modbus slave, etc.
Serial communication function execution methods Ladder program, unit program (flow)
Unit program capacity 3 MB (Max. number of blocks: Approx. 20000)
Max. number of flows 256
Number of simultaneous activities (Flow) Unlimited
Internal data Memory (Flow) 524288 words
Transmission method (PROTOCOL STUDIO) Cyclic communication: Tx + Rx, Tx only, Rx onlyEvent communication: Tx + Rx, Tx only, Rx only, Tx + Continuous Rx, Break Tx
Max. number of connected devices (PROTOCOL STUDIO) 2
Max. number of communication commands (PROTOCOL STUDIO) 48/96*1
Maximum number of total frames (PROTOCOL STUDIO) Rx: 48/96*1× 16;Tx: 48/96*1× 1
Max. number of compared received frames (PROTOCOL STUDIO) 16 per command
Maximum number of block elements (PROTOCOL STUDIO) 96 per frame
Transmission data length (PROTOCOL STUDIO) 1 to 2048 bytes per frame
Communication patterns (PLC link) Write, read, transfer
Number of link settings (PLC link) 512 settings max.*2
Link data size (PLC link) 1440 words max. per setting (bit: 720 words, word: 720 words)737280 words max. (total) (1440 words × 512 settings)
Data unit (PLC link) 1 word
Number of connected models (PLC link) 2 models max. (1 model × 2 ports)
Number of connected units (PLC link) 2 max. (1 unit × 2 ports)
Trigger types (PLC link) Cyclic/event (64 settings max. for event*2)
Update interval (PLC link) 10 to 65535 ms
Internal current consumption 140 mA or less
Weight Approx. 200 g