Thông số Giá trị
Model KL-DC1A
Measurement type DC current
Power voltage 24 VDC ± 10%, Class 2
Operating ambient temperature 0 to +50°C (no freezing)
Operating ambient humidity 35 to 85%RH (no condensation)
Ambient temperature for storage -20 to +70°C
Operating environment Minimal amount of dust and corrosive gas present
Measurement category
Wire temperature rating +70°C or more
Noise immunity 1,500 Vp-p or more, pulse width: 1 µs, 50 ns (by way of a noise simulator), conforms to IEC standards (IEC 61000-4-2/-3/-4/-6)
Withstand voltage 1,500 VAC for 1 minute (between the power supply terminal and each terminal and between all the terminals and the case)
Insulation resistance 100 MΩ or more (tested with a 500 VDC megger, between the power supply terminal and each I/O terminal and between all the terminals and the case)
Internal current consumption (excluding current for driving input circuits) 170mA or less
Shock resistance Conforms to JIS B 3502 and IEC 61131-2, 147 m/s², operating time: 11 ms, 3 times in each of the 3 directions
Pollution degree 2
Intermittent vibration frequency (10 to 57 Hz) Amplitude: 0.075 mm
Intermittent vibration frequency (57 to 150 Hz) Acceleration: 9.8 m/s²
Continuous vibration frequency (10 to 57 Hz) Amplitude: 0.035 mm
Continuous vibration frequency (57 to 150 Hz) Acceleration: 4.9 m/s²
Weight approx 350g
Number of channels 1CH
Number of ranges 5 (Range 1 and range 2 are shared among the terminals.)
Range switching Setting: Use the setting switch. Connection: The connection terminal varies depending on the range.
Input method Single-ended
Sampling rate Normal mode: 1 ms (1,000 times/sec.), high-precision mode: 100 ms (10 times/sec.)
Input range Range 1: 0 to 20 mA, range 2: ±10 mA, range 3: ±100 mA, range 4: ±1 A, range 5: ±10 A
Displayable range (Range 1) -1.00 to 21.00mA
Displayable range (Range 2) -10.999 to 10.999mA
Displayable range (Range 3) -100.99 to 100.99mA
Displayable range (Range 4) -1099.9 to 1099.9mA
Displayable range (Range 5) -10.999 to 10.999A
Normal resolution (Range 1) 10 µA (0.01 mA; 1/2000)
Normal resolution (Range 2) 1 µA (0.001 mA; 1/20000)
Normal resolution (Range 3) 10 µA (0.01 mA; 1/20000)
Normal resolution (Range 4) 100 µA (0.1 mA; 1/20000)
Normal resolution (Range 5) 1mA (1/20000)
High accuracy resolution (Range 1) 0.1 µA (1/200000)
High accuracy resolution (Range 2) 0.1 µA (1/200000)
High accuracy resolution (Range 3) 1 µA (0.001 mA; 1/200000)
High accuracy resolution (Range 4) 10 µA (0.01 mA; 1/200000)
High accuracy resolution (Range 5) 0.1mA (1/200000)
Input impedance (Range 1) 10 Ω
Input impedance (Range 2) 10 Ω
Input impedance (Range 3) 1 Ω
Input impedance (Range 4) 0.1 Ω
Input impedance (Range 5) 10 MΩ
Absolute maximum input current (Range 1) ±100 mA
Absolute maximum input current (Range 2) ±100 mA
Absolute maximum input current (Range 3) ±500 mA
Absolute maximum input current (Range 4) ±3 A
Absolute maximum input current (Range 5) ±12 A
Measurement accuracy (25 ±5°C) Range 1 ±0.2% of F.S. ± 1 digit
Measurement accuracy (25 ±5°C) Range 2 ±0.2% of F.S. ± 1 digit
Measurement accuracy (25 ±5°C) Range 3 ±0.2% of F.S. ± 1 digit
Measurement accuracy (25 ±5°C) Range 4 ±0.3% of F.S. ± 1 digit
Measurement accuracy (25 ±5°C) Range 5 ±0.5% of F.S. ± 1 digit
Measurement accuracy (0 to 50°C) Range 1 ±0.6% of F.S. ± 1 digit
Measurement accuracy (0 to 50°C) Range 2 ±0.6% of F.S. ± 1 digit
Measurement accuracy (0 to 50°C) Range 3 ±0.6% of F.S. ± 1 digit
Measurement accuracy (0 to 50°C) Range 4 ±0.7% of F.S. ± 1 digit
Measurement accuracy (0 to 50°C) Range 5 ±0.9% of F.S. ± 1 digit
Control input 2 (Parameters are used to switch between the KL input, peak/bottom hold control input, and 0-point adjustment input.)
Control output 2 transistor (NPN open-collector) outputs
Setting data Recorded to the EEPROM (rewritable 1,000,000 times)
Other functions Hold (peak and bottom), 0-point adjustment, comparator output, filter setting (LPF and HPF), time average (simple and moving), scaling setting, display unit changing, lock
External calibration input signal number of inputs 2
Maximum input voltage DC26.4V
Input rated voltage DC24V 5.3mA
Minimum ON voltage 19V
Maximum OFF current 1.5mA
Common ground YES
Output voltage 2 outputs (DC1A max., rated output: +24VDC)