Thông số | Giá trị |
---|---|
Model | FD-H32K |
Type | High-temperature model |
Supported pipe diameter | 1″ (25A), ø28–37ø1.10″-1.46″1 1/4″ (32A), ø37–44ø1.46″-1.73″ |
Supported pipe materials | Metal piping, hard plastic piping*1 |
Supported fluids | All fluids (water, oil, chemicals, etc.)*1 |
Supported fluid temperature | 0–180°C32–356°F(no freezing on pipe surface)*2*3 |
Maximum rated flow | 1″ (25A) : 200 L/min52.8 gal/min1 1/4″ (32A) : 300 L/min79.3 gal/min |
Zero cut flow rate | 1.0 L/min0.3 gal/min(variable, initial value) |
Detection principle | Delta TOF + Pulse Doppler |
Function for automatic correction for speed of sound in liquid | Yes |
Display | QVGA 2.0 model: color LCD, status indicator light |
Display update cycle | Approx. 10 times/second |
Display resolution – Instantaneous flow | 0.01/0.1/1 (L/min) (default value: 1) |
Integrated flow | 0.01/0.1/1 (L) (default value: 1; up to 8 digits) |
Response time | 0.5 s / 1.0 s / 2.5 s / 5.0 s / 10.0 s / 30.0 s / 60.0 s / 120.0 s / 200.0 s |
Measurement accuracy | Between 10 and 100% of F.S.: ±3.0% of RD*4*5Between 0 and 10% of F.S.: ±0.3% of F.S.*4*5 |
Repeatability | 0.5 s: ±1.0%, 1 s: ±0.7%, 2.5 s: ±0.45%, 5 s: ±0.3%, 10 s: ±0.2%, 30 s: ±0.15%, 60 s: ±0.1% of F.S.*4*6 |
Hysteresis | Variable |
Flow units | L/min m3/h G/min |
Pulse output increments (L) | 0.02–999.99 |
Pipe temperature measurement accuracy | — |
Network support | IO-Link*7 |
Heat calculation function – Unit | MJ/h kW kBTU/h*8 |
Display resolution | Instantaneous value (MJ/h): 0.01/0.1/1 (default value 0.1); Integrated value (MJ): 0.01/0.1/1 (default value 0.1)*8 |
Pulse output increments (MJ) | 0.02–999.99*8 |
Data accumulation – Accumulation period | Approx. 1 year |
Data reading | USB2.0 |
Power I/O connector | M12 8-pin connector (male) |
I/O (switchable) – Output (Ch1/2/3/4) | Instantaneous flow mode / area mode / pulse output mode / integrated flow mode / bubble detection mode / error outputNPN/PNP setting switching, open collector output 30 VDC or less, max. 100 mA/Ch or less, residual voltage 2.5 V or less |
Analog output (Ch1/2) | 4–20 mA/0–20 mA (switchable), load resistance 500 Ω or less |
External input (Ch2/3) | Integrated reset input / flow-rate zero input / zero-point adjustment input / bank inputShort circuit current: 1.5 mA or less; input time: 20 ms or more |
Power supply – Power voltage | 20–30 VDC, ripple (P-P) 10% included, Class 2/LPS |
Current consumption | 240 mA or less (when using flow sensor standalone; with analog output; excluding load current)*9 |
Protection circuit | Protection against reverse power connection, power supply surges, output short circuits, and output surges |
Environmental resistance – Enclosure rating | IP65/67 (IEC 60529)*10 |
Ambient temperature | Sensor head: −20 to +60°C–4 to +140°F(no freezing); Display unit: −20 to +50°C–4 to +122°F(no freezing)*2 |
Relative humidity | 35–85% RH (no condensation) |
Vibration resistance | 10–500 Hz; Power spectral density: 0.816 G2/Hz; X, Y and Z directions |
Shock resistance | 100 m/s2(approx. 10 G), 16 ms pulses, 1000 times each for X, Y and Z axes |
Material – Display unit | Body: PPS/PET/POM; Display window: PAR |
Sensor head | Body: PEEK/PPS/PET/PAR/SUS304Sensor element: special rubber; Mounting bracket: SUS304/SUSXM7 |
Weight | approx. 680 g23.99 oz |
Cảm biến lưu lượng Keyence FD-H32K
SKU: FD-H32K
Hãng sản xuất: Keyence
Công nghệ: Nhật Bản
Chất lượng: Mới 100%
Bảo hành: Chính hãng
Báo giá
Thông tin bổ sung
Thương hiệu | Keyence |
---|---|
Loại | Cảm biến lưu lượng |